ARL 500 Panel. Elevator Controller Panels
ARL 500 Panel GENERAL FEATURES Communication with Car Units: Serial car communication via CANBus, One to one connection by flexible cables with sockets between the control panel and inspection box, Plug & play connection by one cable with socket between COP and inspection box. Communication with Landing Units. ARL 500 Panel Serial landing communication via CANBus, CANBus line that is joined by cables with sockets from floor to floor and that extends along the shafts, Plug & play connection for landing operation panels by cables with sockets that are connected to shaft CANBus line at each floor. Door Contacts Wiring: Door contact installation that is joined by cables with sockets from floor to floor and that extends along the shaft, Connection for landing doors plug & play contacts by cables with sockets that are connected to door contact installation.
ARL 500 Panel SYSTEM FEATURES Automatic Door Control for any type of door, Independent door control for each floor by double door support 1 door control input/output in inspection box, 2 in control panel Car Positioning By encoder, By magnetic switches and magnets Indicator Options for Car Operating Panel; 240 x 128 pixels graphic LCD indicator 128 x 64 pixels graphic LCD indicator (vertical/horizontal) 2 x 30 mm dot matrix display 3 x 30 mm dot matrix display Call / Indicator Module Options for Landing Operation Panels; 240 x 128 pixels graphic LCD indicator (over a door) 128 x 64 pixels graphic LCD indicator (vertical) 2 x 30 mm dot matrix display 3 x 30 mm dot matrix display Call module without display Emergency Rescue System; By AKUS-SD integration into the control panel (for rope elevators), By adding ARL-SARJ board and 2 pieces of 12V battery (for hydraulic elevators).
ARL 500 Panel Door Bridging; Door pre-opening and door open re-leveling by door bridging relays on mainboard Motor Phase Protection, By in-built inputs/outputs on mainboard Programmable Inputs/Outputs, Free programmable inputs/outputs on the mainboard, car boards and landing boards Test Functions; Special test function to test the connections of car and landing button panels Remote Control; Control of ARL-500 mainboard and ADrive VVVF inverter by hand terminal that is connected to the CANBus line from any point Safety Circuit Connections; Special connections in control panel, inspection box and pit box for safety circuits Car and shaft supply; Earth fault protected fuses for car and shaft lights Shaft light circuit; Shaft light circuit via current pulse relay (activated with buttons in inspection box and pit box) Emergency alarm siren (activated with buttons in inspection box and pit box) Compatibility; EMC tested and verified, Full conformance to EN 81-1/2 +A3 as a complete elevator control system
Reviews
There are no reviews yet.